Search

DF 40 SP ORD LOC
COMBUSTIBLE DUST COLLECTOR

DF 40 SP automatic reverse-air cartridge filter cleaning system

POWER

6.2 | 3~ HP

SURFACE

18,600 in²

CAPACITY

17 gal

The DF 40 SP ORD LOC is a high-airflow combustible dust collector configured for source capture of fine airborne dust in ordinary or unclassified industrial locations. A 6.2 HP, 480 V three-phase fan supports extraction from production machinery, hoods, and properly configured pickup points. Four antistatic polyester M-class cartridges provide 18,600 in² of primary filter area, while the automatic SP reverse-air system cleans the cartridges in sequence to help maintain airflow during dust loading. Compressed air is required for the SP system and is not supplied as standard.

A grounded configuration supports static-control requirements, and collected material is retained in a detachable 17-gal bin. Optional filtration and collection configurations should be identified accurately by quote. Final suitability depends on the material, process conditions, documented area classification, connected hose and accessories, and facility-specific combustible-dust requirements.

HIGHLIGHTS
electric fan

HIGH-AIRFLOW THREE-PHASE FAN

A 6.2 HP, 480 V three-phase electric fan delivers the high-volume airflow required for industrial source capture through extraction arms, hoods, and direct machine connections. Inlet configuration should be matched to the required airflow and pickup design.

antistatic class m filter

ANTISTATIC M-CLASS CARTRIDGES

Four antistatic polyester cartridge filters provide 18,600 in² of primary filtration area. The cartridge configuration is M Class under EN 60335-2-69 and is designed for sustained fine-dust loading in demanding industrial collection applications.

UL Certification

UL certified

The unit is UL certified, ensuring compliance with recognized safety standards for industrial equipment. Its conformity has been verified in accordance with UL 2011, NFPA 79, and UL 508A, confirming adherence to strict electrical and machinery safety requirements. The certification also includes CSA C22.2 No. 14 for Canada, supporting safe use across North American markets.

grounded

GROUNDED ORD LOC CONFIGURATION

The ORD LOC configuration uses grounding and antistatic filtration to support static-control requirements for qualified ordinary-location applications. Final suitability must be confirmed against the collected material, process conditions, connected accessories, and documented facility area classification.

TECHNICAL DATA

Motor

Electric fan
480 | 60
V|Hz
14.6 | 13.4 | 10.6
882 | 1,236 | 1,589
CFM
73
dB(A)
60
Hz
6.2 | 3~
HP
55 | F
6 | 7 ½ | 8
Ø in
single_phase

Primary Filter

4 x Cartidges
M Class
Antistatic polyester
Automatic SP
BGIA M-PES
IFA
18,600
in²
h13

Machine

25 x 44
in
85
in
320
lb
17
gal
OPTIONS

SP – 3C – 14,000

Automatic reverse jet cleaning system. Antistatic M class filter (EN-60335-2-69), 3x Polyester filter cartridges, 14,000 in² filter surface.

ANT

HEPA

H14 Absolute Filter (EN 1822) Glass fiber

BX

GRD

GALLERY
RESOURCES

Place your order

Your Order
Product, SKU, price, standard freight and order total will load automatically from this Commerce Kit.
Shipping currently available within the United States.
Review Your Order
Your product, quantity, standard freight, total and submitted details will be summarized here before submission.
Order verification required
No payment will be collected when you place this order. Depureco will verify the equipment configuration, application, shipping information, tax status, and any applicable safety or compliance requirements before processing. Special freight/accessorial charges may apply when required. All products are sold FOB Origin - Kyle, TX. We will contact you if clarification or changes are required and provide your final invoice and payment instructions after verification.

Contact Us

Request a free quote